Aerogel Insulation Solutions
High-Performance Insulation Where Every Millimetre Matters
Aerogel blanket insulation delivers strong thermal performance in a thin, flexible format. It's an excellent option for renovations and difficult construction details where conventional insulation is too thick or available space is limited.
Where it fits
- Exterior soffits and overhangs with limited insulation depth
- Wall, ceiling and roof upgrades
- Floors, slab edges and difficult perimeter details
- Window and door returns
- Balconies and other thermal-bridge locations
What is aerogel insulation
Aerogel is a highly porous, lightweight material engineered to slow heat transfer. In construction, it's commonly incorporated into flexible blanket products that can be cut, layered and fitted around complex details. Its greatest advantage is high thermal performance within a limited depth.
Vancouver Expert Flooring provides project review, material planning and professional installation for space-constrained aerogel insulation applications in Metro Vancouver. Each assembly is planned around the required R-value, available depth, substrate condition and applicable project specifications.
Why choose aerogel blanket insulation
High performance in a thin profile
Useful when a conventional insulation build-up would be too thick.
Flexible and adaptable
Can be cut and layered to fit soffits, corners, returns and irregular surfaces.
Reduced thermal bridging
Helps improve difficult junctions where continuity of insulation matters.
Well suited to retrofit work
Supports energy upgrades while helping preserve interior space and existing architectural details.
Lightweight material
Adds strong thermal performance without a bulky assembly.
Hydrophobic product options
Selected aerogel blankets can resist liquid-water uptake while remaining vapour open; exact properties are product-specific.
Common applications
- Exterior soffits and overhangs with limited insulation depth
- Wall, ceiling and roof upgrades
- Floors, slab edges and difficult perimeter details
- Window and door returns
- Balconies and other thermal-bridge locations
- Heritage buildings and renovations where space must be preserved
- Tight mechanical or architectural spaces
- Pipes and equipment when the correct industrial-grade product is specified
Our project process
Review
We review drawings, photos, access conditions, available depth and the target thermal performance.
Select
We identify an appropriate aerogel product, thickness and layer arrangement using verified manufacturer data.
Confirm
We check the required technical documentation, including thermal, fire, moisture and installation information.
Prepare
We make sure the substrate and surrounding assembly are ready for a continuous, secure installation.
Install
The blanket is measured, cut, fitted and protected in accordance with the approved system and manufacturer guidance.
Technical planning information
Aerogel is not a single universal product. Thermal resistance, service temperature, fire performance, water-vapour behaviour and installation requirements vary by manufacturer, product grade and thickness. The final assembly is based on the exact product data sheet and your project requirements.
| Planning item | What this means for your project |
|---|---|
| R-value and thickness | We use only the values published for the exact product, test condition and number of layers — never one universal R-value per inch. |
| Fire performance | We confirm the exact fire-test report and the code requirement for your project. CAN/ULC-S114, ASTM E136 and other tests are product- and assembly-specific. |
| Moisture | A hydrophobic blanket isn't a waterproofing membrane, air barrier or vapour retarder unless the complete approved system specifically says so. |
| Service temperature | Building, industrial, cold-service and high-temperature aerogel products aren't interchangeable — we select the correct grade for your application. |
| Substrate and fastening | Fasteners, adhesives, tapes, overlaps and protective layers follow the manufacturer installation guide and the project design. |
| Final assembly | Where required, we coordinate with the architect, building-envelope consultant or engineer to approve the complete wall, roof, soffit, floor or mechanical assembly. |
Installation overview
A typical installation begins with a clean, dry and sound substrate. The aerogel blanket is measured and cut with suitable tools, fitted tightly to reduce gaps, layered where required, and secured with the fastening or adhesive method approved for the system. Joints, penetrations and transitions receive careful attention so the insulation remains continuous. The material is then protected by the specified interior finish, exterior assembly or mechanical jacketing. Our installers follow the product Safety Data Sheet and use appropriate personal protective equipment.
Important system limitations
- Aerogel does not automatically replace required waterproofing, air-barrier or vapour-control layers.
- A product described as hydrophobic is never advertised as waterproof.
- Non-combustibility or fire resistance is never claimed without the exact supporting test report.
- Structural loading, compression and finish requirements are evaluated for floor and traffic-bearing applications.
Frequently asked questions
Is aerogel better than conventional insulation?
Aerogel provides very high thermal performance for its thickness, which makes it especially valuable where space is limited. Conventional insulation may remain more economical where there's plenty of cavity depth. The best choice depends on the complete project.
Can aerogel help achieve an R-25 target?
It can be an effective solution when an R-25 target must fit within a shallow space. The required thickness is calculated from the verified thermal data for the selected product and the complete assembly, including thermal bridges.
Is every aerogel blanket non-combustible?
No. Fire performance varies by product and facing. We confirm the exact report required by your project rather than applying one claim to every aerogel product.
Is aerogel waterproof?
No. Some blankets are hydrophobic and resist liquid-water uptake, but that doesn't make them a substitute for waterproofing or building-envelope membranes.
Can aerogel be installed over an existing surface?
Sometimes. The substrate must first be checked for moisture, contamination, damage, adhesion, fastening capacity and compatibility with the proposed assembly.
Why use aerogel if the material cost is higher?
In tight spaces, aerogel can avoid major changes to walls, soffits, ceilings or architectural details. The value comes from achieving thermal performance while preserving usable space and simplifying difficult construction conditions.
Technical documents
Product data sheets, safety data sheets and compliance reports are published here once we've confirmed the exact product for your project. In the meantime, request a project assessment and we'll send the current documents for the system we recommend.
Have a difficult insulation detail?
Have a difficult insulation detail or limited cavity depth? Send us your drawings, photos, available space and required R-value — we'll review the application and recommend the next step.
Aerogel product properties and installation requirements vary by manufacturer, grade, thickness and assembly. Final recommendations are subject to review of the current technical data, project conditions and applicable codes.